| ●With Stabilizer Function | |||
| ●Wide Input Voltage Range | |||
| ●Wide Input Frequency Range | |||
| ●High/Low Voltage Protection, Overload/Short Protection | |||
| ●Cool start computer even there isnt main power | |||
| ●Automatic recharge even UPS is off | |||
| ●Automatic restart | |||
| ●Beeping Alarm on Battery, Battery Low and Overload | |||
| ●Beeping Selection | |||
| ●Intelligent Battery Management | |||
| ●Intelligent LCD Display | |||
| ●Smart RS232& RJ11& USBOption | |||
| ●Compatibility with generators | 
| Overview | 
|              Product  |                          Requirements  |                          Model 1  |                          Model 2  |                          Model 3  |                          Model 4  |                          Model 5  |                          Model 6  |         
|              Power (VA)  |                          PCA-500  |                          PCA-650  |                          PCA-800  |                          PCA-1000  |                          PCA-1200  |                          PCA-1500  |         |
|              Input  |                          Voltage  |                          80-150VAC / 145-290VAC ±5V  |         |||||
|              Frequency  |                          60/50Hz+/-10%  |         ||||||
|              Output  |                          Voltage (AC Mode)  |                          105-135VAC / 190-250VAC  |         |||||
|              Voltage (Inverter Mode)  |                          120VAC / 220VAC ±5%  |         ||||||
|              Capacity  |                          500VA/300W  |                          650VA/360W  |                          800/480W  |                          1000VA/600W  |                          1200/720W  |                          1500VA/880W  |         |
|              Frequency (Inverter Mode)  |                          60/50Hz+/-0.5Hz  |         ||||||
|              Transfer Time  |                          2ms typical  |         ||||||
|              Generator connection  |                          Normal Working under the Generator  |         ||||||
|              Waveform  |                          modified-Sinewave  |         ||||||
|              Protection  |                          Spike & Surge Suppression  |                          yes  |         |||||
|              Over/Under Volt.  |                          Switch to Bat.O / Pwhen Mains over regulation range  |         ||||||
|              Over load /short Circuit  |                          Fuse & current limited for both Mains and Battery modes  |         ||||||
|              Battery  |                          Type  |                          Lead-Acid maintenance-free  |         |||||
|              Dc Bus  |                          12V7.0Ah  |                          12V9.0Ah  |                          12V7.0Ah  |                          12V9.0Ah  |         |||
|              Number  |                          1 PC  |                          1  |                          2 PCS  |         ||||
|              Recharge time  |                          8hours≥90%  |         ||||||
|              Back up time(one PC)  |                          8-15mins  |                          10-18mins  |                          15-25mins  |                          20-30mins  |                          20-30mins  |                          25-45mins  |         |
|              Physical  |                          Weight (KGs)  |                          5  |                          5.5  |                          6  |                          10.5  |                          11  |                          11.5  |         
|              ShippingWt.  |                          5.6  |                          6  |                          6.5  |                          11  |                          11.5  |                          12  |         |
|              Product Dimensions (mm)  |                          335*95*160  |                          355*120*195  |         |||||
|              Packing Dimensions (mm)  |                          395*360*230 mm/ 2 PCS in 1 Carton  |                          435*395*275/ 2 PCS in 1 Carton  |         |||||
|              Soft ware  |                          RS232 or USB optionWindows & NT  |                          Auto save & shut down  |         |||||
|              Function  |                          Cold start  |                          UPS Start The Computer Even there Is no Main Power  |         |||||
|              Automatic Charge  |                          Automatic Charge when UPS is off  |         ||||||
|              Automatic Restart  |                          Automatic Restart if main power coming within one hour  |         ||||||
|              Voltage display  |                          220v/230v Optionalfollowing the real capacity  |         ||||||
|              Frequency  |                          50HZ/60HZ Optioanl following the real  |         ||||||
|              Beeping  |                          During the battery mode ,the beeping optional  |         ||||||
|              Efficiency  |                          AC-AC  |                          1  |         |||||
|              DC-AC  |                          0.6  |         ||||||
|              Acoustic  |                          Noise level  |                          ≤45dB  |         |||||
|              Environmental  |                          Temperature  |                          -5-45 DegreeC  |         |||||
|              Humidity  |                          20% to 90%  |         ||||||
|              Power Outlets  |                          No. and types  |                          2SOCKETS  |                          3 SOCKETS  |         ||||